Syringe pump SP-8800
Manufacturer AMPall – Origin Korea
Overview
- Faster, Easter and Precise
- Numerical keypad Easy and fast way to setup
- Simple, fast and convenient syringe installation
- Color LCD, Display complete infusion information
Introduce
SP-8800 electric syringe is used for infusion of chemical solution such as vasoconstrictor, analgesic, anticoagulant, anesthetic, anti-cancer, Oxytonic, nutrients. The device is designed for high flow rate accuracy and is easy to handle infusion solution when equipped with the most advanced audible and visual alarm system and sensor types.
Feature
- Self testing – Every time the unit is turned on, self testing is proceeded.
- Automatic syringe detection – Detect syringe size automatically. (10, 20, 30, 50ml )
- Shortcut key – Syringe brand set, Occlusion set, Buzzer level set
- K.V.O.(Keep Vein Open) – When the delivery volume has been reached, flow rate turns into K.V.O. rate (adjustable from 0.1ml/h to 10ml/h) automatically.
- Keypad lock function – Keypad is locked with or without password depends on its using condition.
- Infusion setup – Flow rate/ Delivery volume/ Infusion time
- Retain memory – Last setting value is retained.
- Infusion remaining time display
- Alarm repeat function
- Open system – Calibration up to 10 syringe brands in a single unit.
- Buzzer level – 3steps
- Occlusion level – 9steps (3.8psi~19.3psi)
- Purge rate – Adjustable (0.1~1200ml/h)
- Bolus rate – ON/OFF, Adjustable (0.1~1200ml/h, 0.1~1000ml)
- Anti bolus – Reduce significantly bolus after occlusion release. (ON/OFF)
- History call back – Call back last 10 infusion data.
- Dosage mode(Body weight mode) – Automatically calculate and set a proper flow rate when dose rate, body weight, drug mass and solution volume are entered. (Option)
- Date storage – With power off, stroed data will go for 5years.
- Strengthening safety – Dual CPU stops the device when malfunction is happened.
- Unit setup for Dosage mode – ml/h, mg/kg/h, mg/kg/min, ㎍/ kg/h, ㎍/ kg/min
- Nurse call – Each unit can be connected with nurse call system (DC 24V, 0.5A) (Option)
- Profile function – Program infusion condition (flow rate, delivery volume, delivery time) differently for every hour, up to 24hours. (Option)
- Central system – Connect with main PC for monitoring (Option)
Specification
- Flow rate range:
- syringe 10ml: 0.1 ~ 300ml/h
- syringe 20ml: 0.1 ~ 400ml/h
- syringe 30ml: 0.1 ~ 500ml/h
- syringe 50ml: 0.1 ~ 1200ml/h
- Delivery volume: 0.1 ~ 1000ml
- Total infused voume (volume to be infused): 0.1 ~ 1000ml
- Accuracy:
- Within ±1% on mechanism
- Within ±3% on approved syringe
- Alarms (audio & visual): 0cclusion, K.V.0.(Infusion Completion), Standby, Near empty, Low battery, Device malfunction, Glamp/Handle lever/Slider disengaged, Syringe disengaged
- Special funtion: Keypad lock, Shortcut key, Retain memory, Remaining time, Alarm repeat, 0pen system, K.V.0.,Purge, Bolus, Anti bolus, 0cc. level, History call-back, Dosage mode(0pfion), Nurse call(Option), Profile(0ption), Drug labeling(0ption), Central system(0ption)
- Weight: Approximately 2.5kg (without rechargeable battery 2kg)
- Dimension: 220 x 130 x 108 (mm)
- Power consumption: 18VA
- Power requirements: AC110/230V, 50/60Hz hoặc DC9.6V, DC12V/24V,2A
- Battery type: Ni-MH rechargeable battery
- Battery operating time: 2 giờ
- Battery recharging time: 6 giờ
- Operating condition: 5 ~ 400C, 30 ~ 90% RH (no condensation)
- Storage condition: -20 ~ 450C, 10 ~ 95% RH (no condensation)
Reviews