1 Channel ECG – BPL
Model: Cardiart GenX1
Manufacturer: BPL – Origin: India
FEATURE
- ECG Analysis & Interpretation: Gender, age & race specific advanced ECG analysis & interpretation – The Glasgow ECG Interpretation Algorithm
- Short Recharge Time: Rechargable lithium battery with fast charge feature
for energy efficient operation - Large character LCD display: Dual row, cool blue, large character LCD Display with
adjustable contrast. - Ergonomic Design: Enhanced portability with built-in power supply & integral handle
- PC Interface: Interfaces with PC using optional Rt-View software
- Soft Silicone Keypad: Soft silicone keys for ease of operation
- HRV assessment: Equipped with with Short term HRV assessment
- Multiple Operating Modes: Auto & manual modes with selectable rhythm option
- Thermal printer: 58 mm wide paper for clear trace prints.
- Internal record storage: Stores up to 20 records internally
SPECIFICATIONS
- Power supply: 100 to 240VAC; 50 / 60 Hz
- Power Consumption: Less than 40VA
- Battery Capacity: Auto Mode: 200 ECG’s in 1 channel format @25 mm/sec, 10mm/mV, 2.5 s; Normal trace & Interpretation – OFF
- Mains protection: Fuse: T2A 250 V
- Battery Protection: In built PCM Module
- Battery Charging time: Approximately 3 hours from total discharge (Unit off)
- ECG Acquisition: 12 bits; 1000 samples/sec/channel;
- ADC Resolution: 2.55 μV/LSB
- Input Dynamics: DC offset: ± 300mV; AC Differential: ± 5mV in the pass band
- ECG Leads: Standard 12 leads or Cabrera; Acquired 8 leads & Reconstructed 4 leads (Lead III, Lead aVR, Lead aVL, Lead aVF)
- Recording sensitivity: Manual: 2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% Auto: dependent on the signal strength,
Optimizes automatically to 2.5mm/mV,5mm/mV,10mm/mV, 20mm/mV ± 5% - Input Impedance: Greater than 10 MΩ @ 10 Hz
- Frequency Response: 0.05 Hz to 150 Hz (-3dB) without Mains /Muscle and ADF Filters.
- ECG Analysis & Interpretation: Gender, Age & Race specific Advanced ECG Analysis & Interpretation – University of Glasgow in auto mode
- ECG analysis sampling rate: 500 samples/second (sps)
- Filters: Mains interference/Muscle filter: Linear phase digital 50Hz Notch filter with selectable 32Hz.
– Anti-drift filter : Selectable Digital 0.5Hz Anti Drift High pass linear phase filter - Display: Large, 16 x 2, Blue, Alphanumeric Display
- Keyboard: Silicone Rubber keypad
- Paper transport speed: 5 mm/sec or 12.5 mm/sec or 25mm/sec or 50 mm/sec
- Print formats: Manual: 1 Ch. Auto: 1 Ch, 1 Ch + 1 Rhythm with selectable print durations of 2.5 secs. / 5 secs. / 10 secs.
- PC connectivity: ECG transfer to PC through Rt-VIEW SOFTWARE(Optional)
- Operating Temperature: +10 to +40 °C
- Relative Humidity: Upto 95% RH non-condensing.
- Safety Classification: Class I with internal power supply
- Degree of protection: Type CF
- Dimension: Approx. 300mm x 260mm x 80 mm (length x width x height)
- Weight: Approx. 2 Kgs.